We may earn a commission when you buy through our links. It never changes our picks. How we pick →
Portable Power Station: What It Will Really Run (2026)
Decode the numbers on the box one at a time, then work out your own runtime with a simple formula.
Gear Receipts Desk· 8 sources· Updated Nov 21, 2026
Divide the battery's watt-hours by your load in watts, after you take off the losses. ReeWray Outdoors says to expect maybe 80 or 85 percent of the rated capacity, and Enerbe says LiFePO4 is rated for 3,000 to 6,000+ cycles at 80% depth of discharge.
Watch the videoJump to a section
Watch the explainer
The numbers that matter
Typical usable share of rated capacity
Receipt · ReeWray Outdoors80-85% Typical usable share of rated capacityRead Nov 20, 2026Open source ↗Usable capacity measured on the Predator 350
Receipt · Footprint Hero81.6% Usable capacity measured on the Predator 350Read Nov 20, 2026Open source ↗Usable capacity for a 12 V fridge over 40 hours
Receipt · ReeWray Outdoors800 Wh Usable capacity for a 12 V fridge over 40 hoursRead Nov 20, 2026Open source ↗Battery used by one full kettle on the Elite 300
Receipt · WIRED7% Battery used by one full kettle on the Elite 300Read Nov 20, 2026Open source ↗Watts or watt-hours: which is the tank?
Watt-hours are the size of the tank. Watts are how fast you pull from it right now. Wild Smart Gear puts it this way: watts measure power at a moment, watt-hours measure energy over time. Receipt · Wild Smart GearWatts versus watt-hours, amp-hour conversionRead Nov 20, 2026Open source ↗
The math is power times time. For a constant 50 W load running for 4 hours, energy is 50 × 4 = 200 Wh. Receipt · Wild Smart GearWatts versus watt-hours, amp-hour conversionRead Nov 20, 2026Open source ↗
A big number on the box may be output, not storage. TechRadar lists the EcoFlow Delta 3 Plus at 1024Wh of battery capacity and 2400W of output. Receipt · TechRadarEcoFlow Delta 3 Plus specs and UPS testRead Nov 20, 2026Open source ↗
Some batteries list amp-hours instead. Multiply by voltage: a nominal 12.8V, 100Ah battery is about 1280Wh on that nominal basis. Receipt · Wild Smart GearWatts versus watt-hours, amp-hour conversionRead Nov 20, 2026Open source ↗
- A station advertised as 2000W is not necessarily storing 2000Wh. Receipt · Wild Smart GearWatts versus watt-hours, amp-hour conversionRead Nov 20, 2026Open source ↗
How much capacity can you really use?
ReeWray Outdoors says nearly every station posts the theoretical total maximum capacity of its internal battery cells. Real access is lower because of AC inverter conversion losses and power reserved for the battery management system (BMS). Receipt · ReeWray OutdoorsUsable capacity, fridge math, watt meterRead Nov 20, 2026Open source ↗
The same reviewer says to expect maybe 80 or 85 percent of the rated capacity. WIRED reported the Bluetti Elite 300 at consistently around 85 percent. Footprint Hero measured 240 Wh from the Predator 350's 294 Wh battery, which is 81.6% usable. Receipt · ReeWray OutdoorsUsable capacity, fridge math, watt meterRead Nov 20, 2026Open source ↗
Part of the loss is the inverter. Powergetup says a 97% inverter wastes 3% as heat. A battery delivering 1000 Wh DC yields 950 Wh AC with a 95% inverter. Receipt · PowergetupInverter efficiency and runtime formulaRead Nov 20, 2026Open source ↗
Powergetup adds that efficiency varies with load and peaks roughly between 30% and 80% of rated capacity. The formula to use: usable hours = battery Wh × efficiency / load W. Receipt · PowergetupInverter efficiency and runtime formulaRead Nov 20, 2026Open source ↗
What are running watts and surge?
Rated output is how much the station can push out continuously. Wild Smart Gear says to check the continuous output limit first. Footprint Hero notes some boxes call this running watts. Receipt · Wild Smart GearWatts versus watt-hours, amp-hour conversionRead Nov 20, 2026Open source ↗
Motors and compressors pull a burst when they start. ReeWray Outdoors says a 12 V fridge needs about 45 Watts while the compressor runs, with a momentary peak surge of somewhere around 200 Watts at startup. Receipt · ReeWray OutdoorsUsable capacity, fridge math, watt meterRead Nov 20, 2026Open source ↗
Limits can stack. WIRED says the Jackery Explorer 1500 Ultra can put out 1,800 watts steadily, jump to 2,000 watts for up to 15 minutes, and handle 3,600 watts for very short bursts. Footprint Hero lists the Predator 350 at 350 running watts and 700 starting watts. Receipt · WIREDBluetti Elite 300 and Jackery 1500 Ultra figuresRead Nov 20, 2026Open source ↗
Surge has a cost. When a load exceeds the Bluetti Elite 300's 2,400-watt maximum, surge mode gives a couple of minutes at up to 4,800 watts. WIRED says boiling a full kettle drained 7 percent of the battery. Receipt · WIREDBluetti Elite 300 and Jackery 1500 Ultra figuresRead Nov 20, 2026Open source ↗
How long will a fridge run? The math
ReeWray Outdoors says a typical 12 volt DC fridge freezer uses about 20 watt hours for every hour of use, with the compressor cycling on and off. A two-day weekend equates to 40 hours of runtime. Receipt · ReeWray OutdoorsUsable capacity, fridge math, watt meterRead Nov 20, 2026Open source ↗
Multiply 20 watt hours by 40 hours and you need a usable battery capacity of at least 800 watt hours. Because only a slice of the rated capacity is usable, the rated number has to be higher. Receipt · ReeWray OutdoorsUsable capacity, fridge math, watt meterRead Nov 20, 2026Open source ↗
The station also draws power itself. Footprint Hero calculated around 5.88 Watts idle AC power draw on the Predator 350. Its manual says the AC outlets automatically cut off after 1 hour, so check that before trusting it with a fridge. Receipt · Footprint HeroPredator 350 measurements and screen readingRead Nov 20, 2026Open source ↗
For your own numbers, ReeWray Outdoors recommends an inexpensive watt meter, less than 20 bucks or right around there, and calls it well worth it. Receipt · ReeWray OutdoorsUsable capacity, fridge math, watt meterRead Nov 20, 2026Open source ↗
LiFePO4 or lithium-ion: which lasts longer?
LiFePO4, also written LFP, is lithium iron phosphate. Enerbe says it was designed from the start for deep cycling and safety. Phone and laptop batteries use NMC or NCA, which stores more energy per pound but wears out faster and runs hotter. Receipt · EnerbeLiFePO4 versus NMC cycles and cold chargingRead Nov 20, 2026Open source ↗
Enerbe lists quality LiFePO4 at 3,000-6,000+ cycles at 80% depth of discharge. It says NMC only lasts 1,000-2,000 cycles. Receipt · EnerbeLiFePO4 versus NMC cycles and cold chargingRead Nov 20, 2026Open source ↗
Project Farm said every station in its 2,000 W-class comparison uses lithium iron phosphate batteries. For one Anker model, the claim is at least 80% capacity after 4,000 cycles. That is the kind of figure to look for. Receipt · Project Farm2,000 W-class comparison, LiFePO4, Anker cycle claimRead Nov 20, 2026Open source ↗
There are tradeoffs. Enerbe lists no charging below 0°C without heating. ReeWray Outdoors says constantly fast charging, fast discharging or extreme heat can speed up capacity loss. Receipt · EnerbeLiFePO4 versus NMC cycles and cold chargingRead Nov 20, 2026Open source ↗
- If the listing does not say LiFePO4 or LFP, ask. Receipt · EnerbeLiFePO4 versus NMC cycles and cold chargingRead Nov 20, 2026Open source ↗
What do input watts, solar and UPS mean?
Input watts show how fast the station refills. Footprint Hero says the Predator 350's wall charger is listed at 100 W max, and it pulled 76 watts. The box says 4.1 hours to AC charge it. Receipt · Footprint HeroPredator 350 measurements and screen readingRead Nov 20, 2026Open source ↗
Bigger stations charge much faster. WIRED says the Bluetti Elite 300 can pull 2,300 watts from the wall to hit 80 percent in an hour and a half. Standard charging is better for the battery and takes around three hours. Receipt · WIREDBluetti Elite 300 and Jackery 1500 Ultra figuresRead Nov 20, 2026Open source ↗
Solar input is the most the station accepts from panels. WIRED lists up to 1,200 watts of portable solar for the Elite 300. Project Farm lists an EcoFlow in its comparison at up to 500 W. Check this before you buy panels. Receipt · WIREDBluetti Elite 300 and Jackery 1500 Ultra figuresRead Nov 20, 2026Open source ↗
UPS mode takes over if the grid cuts out. TechRadar credits the Delta 3 Plus with a 10ms switchover, and its router, laptop and lights stayed on through simulated outages. WIRED lists the same 10-millisecond delay for the Elite 300. Receipt · TechRadarEcoFlow Delta 3 Plus specs and UPS testRead Nov 20, 2026Open source ↗
- Flaw: the Elite 300 weighs just under 58 pounds and is not expandable, per WIRED. Receipt · WIREDBluetti Elite 300 and Jackery 1500 Ultra figuresRead Nov 20, 2026Open source ↗
Can you trust the station's screen?
Not fully. Footprint Hero found the Predator 350's wattage was suspiciously close to the volt amps, as if it was not accounting for the power factor, which was around 0.5 in that case. Receipt · Footprint HeroPredator 350 measurements and screen readingRead Nov 20, 2026Open source ↗
Five other stations from three brands displayed numbers a lot closer to watts. Even those varied a little, so take the numbers with a grain of salt. For anything that matters, use a plug-in watt meter. Receipt · Footprint HeroPredator 350 measurements and screen readingRead Nov 20, 2026Open source ↗
Three things to remember. Watt-hours are the tank and watts are how fast you drain it. Plan on about 80 or 85 percent of the rated capacity. For years of use, look for LiFePO4. Receipt · ReeWray OutdoorsUsable capacity, fridge math, watt meterRead Nov 20, 2026Open source ↗
Products mentioned
1024Wh capacity, 2400W output, 10ms UPS Receipt · TechRadarEcoFlow Delta 3 Plus specs and UPS testRead Nov 20, 2026Open source ↗
Around 85 percent usable, 2,300 W wall charging Receipt · WIREDBluetti Elite 300 and Jackery 1500 Ultra figuresRead Nov 20, 2026Open source ↗
81.6% usable, screen showed volt-amps Receipt · Footprint HeroPredator 350 measurements and screen readingRead Nov 20, 2026Open source ↗
Stacked limits: 1,800 W, 2,000 W, 3,600 W Receipt · WIREDBluetti Elite 300 and Jackery 1500 Ultra figuresRead Nov 20, 2026Open source ↗
Work out your load in watts and watt-hours with a plug-in watt meter, then plan on using about 80 or 85 percent of the rated capacity. Choose LiFePO4 if you want it to last, and treat the screen reading as a rough guide.
Questions people ask
What is the difference between watts and watt-hours on a power station?
How much of a power station's rated capacity can you actually use?
How do you work out the real runtime?
Is LiFePO4 better for a power station?
Can you trust the watts shown on the station's screen?
Did you test these yourselves?
Every number on this page links to one of these. How we pick